Stage Lighting Installation Seven Notices Stage lighting is one of the many forms of stage art. It uses stage lighting equipment (such as lighting fixtures, slides, control systems, etc.) and technical means to display the environment with lighting color and its changes, rendering atmosphere, highlighting the central character, and creating stage space. Feelings, sense of time, shaping the external image of the stage performance, and provide the necessary lighting effects.

Stage Lighting Installation Seven Major Precautions The current mainstream entertainment venues, such as KTV, bars, nightclubs and other places of decoration design are inseparable from the LED lighting equipment, corresponding to the national economy is the level of improvement, people's cultural quality continues to rise, the stage design in The proportion of the entire performance is getting heavier. In the following, the author will introduce seven issues that we should pay special attention to when installing LED lighting equipment in the early stage.

(I) Precautions against static electricity ESD mark 1. The operator must wear a grounded anti-static wrist strap and wear anti-static shoes and anti-static clothing.

2. If the LED is damaged by static electricity, it will show some bad characteristics: the leakage current increases, the static forward voltage decreases or rises, and it does not shine or emits light under low current test.

3, all equipment and instruments that contact the LED must be well grounded, especially soldering iron and tin furnace must be well grounded.

4, anti-static wrist must be tested every day, failed must be replaced.

(B) pin forming method 1, the stent forming must be done with a jig or a professional.

2. The forming of the bracket needs to ensure that the pins and spacing are consistent with the circuit board.

3, must be 2 mm away from the colloid to bend the stent, so as not to cause colloidal rupture or damage the internal structure.

4. Bracket forming must be completed before welding.

Page 2: Other Installation Precautions (III) Use of Current 1. Excessive current may cause the LED lamp to burn or reduce its brightness.

2. Since the LED has a characteristic that the current increases rapidly with a slight increase in the voltage.

3, in use should be added a resistor and LED lights in series, play a role in limiting.

4. The LED should work under the same current conditions. It is generally recommended that the LED current be 15-19mA.

(D) LED welding conditions 1, soldering iron welding: soldering iron (up to 30W) tip temperature does not exceed 300 °C; welding time does not exceed 3 seconds; welding time does not exceed 3 seconds; welding position at least 3 mm from the colloid.

2, dip solder: dip solder maximum temperature of 260 °C; dip soldering time of not more than 5 seconds; dip soldering position at least 2 mm from the colloid.

(5) Testing of brightness and instructions for use of the product 1. When using products that use split-light separation, please sort and use according to the sequence of the BIN number. Do not mix LEDs of different BIN numbers in the same product to avoid color and brightness. The difference in voltage. If you want to mix BIN numbers, adjacent BIN numbers can be put together but try to avoid them.

2. When detecting and using LEDs, it is necessary to provide the same current or constant current detection to each LED so as to ensure that the detection brightness is consistent. The current should not exceed 20mA, and it is best to use a current of 15-19mA.

(Six) LED installation method 1, be sure not to install the LED in the case of pin deformation.

2, when installing the LED, Jian intend to use guide sleeve positioning.

3, pay attention to the arrangement of various types of devices outside the line to prevent the wrong polarity. The device must not be placed too close to the heating element.

4. When you decide to install in a hole, calculate the size and tolerances of the holes on the face and the circuit board to avoid overstressing the bracket.

5. Before the soldering temperature returns to normal, the LED must be protected from any vibration or external force.

(vi) Cleaning Care must be taken when cleaning colloids with chemicals because some chemicals cause damage to the colloidal surface and cause fading such as trichloroethylene, acetone, etc. Ethanol can be used to wipe and dip. The time should not exceed 3 minutes at room temperature.

The above is the Stage Lighting Installation Seven Notices we have listed for you. You can submit the following form to obtain more industry information we provide for you.

You can visit our website or contact us, and we will provide the latest consultation and solutions

Share to:

Send Inquiry

Home> Industry Information> Stage Lighting Installation Seven Notices
Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send